Programming
menu
|
Menu No
|
Menu Description
|
Default Values
|
|
1
|
change lock tes code
|
2580
|
|
2
|
change auxillari test code
|
0.852
|
|
3
|
change programming code
|
1234
|
|
4
|
change normal/secure code
|
3838
|
|
5
|
change normal/bypass code
|
-
|
|
6
|
change door activation time
|
4
|
|
0
|
return to factory default
|
1234
|
Programming
mode
Enter
programming mode ## 1234 (## means pressing # for 3 seconds)
Menu 0 –
reset to factory default settings
|
key entry
|
resault
|
|
## 1234-0-1234
|
reset to factory defaults with 4-digit code length
|
Menu 1 – changes the lock output test code 1
|
key entry
|
resault
|
|
## 1234-1-9360
|
sets the lock output test code 1 to 9360
|
Menu 2 –
changes the lock output test code 2
|
key entry
|
resault
|
|
## 1234-2-7481
|
Sets the lock output test code 2 to 7481
|
Menu 3 –
changes the programming code
|
key entry
|
resault
|
|
## 1234-3-3748
|
Sets the programming code to 3748
|
Menu 4 –
changes the normal/secure code
|
key entry
|
resault
|
|
## 1234-4-4856
|
Sets the normal / secure code to 4856
|
|
## 1234-4-0000
|
Disables secure mode
|
Menu 5 –
changes the normal / bypass code
|
key entry
|
resault
|
|
## 1234-5-6754
|
Sets bypass code to 6754 with door chime enable (last
digit greater than zero)
|
|
## 1234-5-6750
|
Sets the bypass code to 6750 with door chime
disabled (last digit equal to zero)
|
|
##1234-5-0001
|
Disables bypass mode with door chime enabled
|
|
##1234-5-0000
|
Disables bypass mode and door chime
|
Menu 6 – set
the lock
|
key entry
|
resault
|
|
## 1234-6-0015
|
Sets the lock open time to 15 seconds with relay set to
fail secure (1st digit) and sirene disabled (2nd digit)
|
|
## 1234-6-1215
|
Sets the lock open time to 15 seconds with relay
set to fail safe (1st digit) and siren for 2 min (2nd
digit)
|
Menu 7 –
adds user codes
|
key entry
|
resault
|
|
## 1234-7-001-3456##
|
Adds single user, sets code 3456 to user number 001
|
|
## 1234-7-039-5678-458-6789##
|
Adds non-sequential users, sets code 5678 to user number
039, and then sets code number 6789 to user number 458
|
|
##1234-7-275-3636#3344
|
Adds sequential users, sets code 3636 to user
number 275, and then sets code number 3344 to user number 276
|
|
##1234-7-000-5656-6754##
|
Adds secondary code 6754 to user with primary code 5656
|
Menu 8 –
deletes user codes
|
key entry
|
resault
|
|
## 1234-8-005-1234
|
Deletes user number 005
|
|
## 1234-8-000-3456-1234
|
Deletes user with code 3456
|
Tambahan
settingan :
##1234-6-1005 : untuk mereset keypad
##1234-6-1105
: setting dari NO to NC
##1234-6-0005 :
setting dari NC to NO
Reset mesin
access door dengan cara tekan tombol button cabut adaptor dan nyalahkan kembali
dan jangan lepas button setelah sepuluh detik.